Property | Description | Specification | Unit | |||||
---|---|---|---|---|---|---|---|---|
15A | 25A | 35A | 45A | 60A | 80A | |||
Discharge | Constant discharge current | 15 | 25 | 35 | 45 | 60 | 80 | A |
Discharge Peak current | 50±30 | 60±30 | 100±50 | 180±10 | 180±10 | 220±100 | A | |
Over current protection | 50±30 | 60±30 | 100±50 | 180±10 | 180±10 | 220±100 | A | |
Charge | Charge Voltage | Series No. x 4.2V | V | |||||
Charge current | <15 | <25 | <35 | <45 | <60 | <80 | A | |
Over charge protection | Over charge detect voltage | 4.25±0.025 | V | |||||
Over charge protection delay | 0.5 | S | ||||||
Over charge release voltage | 3.55±0.05 | V | ||||||
Balance | Balance detect voltage | 3.5 | V | |||||
Balance release voltage | 3.5 | V | ||||||
Balance current | 35±5 | mA | ||||||
Over discharge protection | Over discharge detect voltage | 2.2±0.1 | V | |||||
Over discharge detect delay | 1 | V | ||||||
Over discharge release voltage | 2.7±0.05 | V | ||||||
Over current protection | Over current detect delay | 1 | MS | |||||
Over current protection release condition | Off load | |||||||
Short circuit protection | Short circuit protection condition | Short circuit of external load | ||||||
Short circuit detect delay | 250 | uS | ||||||
Short circuit protection release condition | Off load | |||||||
Temp Protection | Temp Protection | none can be customized |
? | |||||
Inner resistance | Conductive resistance in main circuit | =20 | mO | |||||
Electricity self consume | Working current | ~100 | uA | |||||
Sleeping current(battery over discharged) | ~20 | uA | ||||||
Work Temp | Temp range | -40 - 80 | ? | |||||
Size | Size | 15A and 25A(64x50x11), 35A and 45A (80x61x11), 60A(80x61x16) |
mm |
Property | Description | Specification | Unit | |||||
---|---|---|---|---|---|---|---|---|
80A | 100A | 120A | 150A | 200A | 250A | |||
Discharge | Constant discharge current | 80 | 100 | 120 | 150 | 200 | 250 | A |
Discharge Peak current | 260 | 300 | 360 | 450 | 500 | 600 | A | |
Over current protection | 80 | 100 | 120 | 150 | 200 | 250 | A | |
Charge | Charge Voltage | Series No. x 4.2V | V | |||||
Charge current | 80 | 100 | 120 | 150 | 200 | 250 | A | |
Over charge protection | Over charge detect voltage | 4.25±0.025 | V | |||||
Over charge protection delay | 0.5 | S | ||||||
Over charge release voltage | 4.15±0.05 | V | ||||||
Balance | Balance detect voltage | 4.18 | V | |||||
Balance release voltage | 4.18 | V | ||||||
Balance current | 30±5mA | mA | ||||||
Over discharge protection | Over discharge detect voltage | 2.7±0.05 | V | |||||
Over discharge detect delay | 0.5 | V | ||||||
Over discharge release voltage | 3.0±0.05 | V | ||||||
Over current protection | Over current detect voltage | 150 | mV | |||||
Over current detect delay | 9 | MS | ||||||
Over current protection release condition | Off load | |||||||
Short circuit protection | Short circuit protection condition | Short circuit of external load | ||||||
Short circuit detect delay | 250 | uS | ||||||
Short circuit protection release condition | Off load | |||||||
Temp Protection | Temp Protection | 65? or 75? | ? | |||||
Inner resistance | Conductive resistance in main circuit | ~10 | mO | |||||
Electricity self consume | Working current | ~40 | uA | |||||
Sleeping current(battery in discharge) | ~20 | uA | ||||||
Work Temp | Temp range | -30 - 80 | ? | |||||
Size | Size | 80A (150x650x27), 100-150A (150x650x30) |
mm |